产品类别

1KV 架空绝缘电缆
1KV Aerial Insulated Cable

电缆型号 Type and Description


型号 Type

名称 Description

适用范围 Application

JKV JKLV

铜(铝)芯聚氯乙烯绝缘架空电缆 Copper(aluminum)conductor,PVC insulated aerial cable

用于架空固定敷设及引户线
Applying in cable fixed aerial laying or used as wire leading into user's premises

JKY JKLY

铜(铝)芯聚乙烯绝缘架空电缆 Copper(aluminum)conductor,PE insulated aerial cable

JKYJ JKLYJ

铜(铝)芯交联聚乙烯绝缘架空电缆 Copper(aluminum)conductor,XLPE insulated aerial cable

JKLHV

铝合金芯聚氯乙烯绝缘架空电缆 Aluminum alloy conductor,PVC insulated aerial cable

JKLHY

铝合金芯聚乙烯绝缘架空电缆 Aluminum alloy conductor,PE insulated aerial cable

JKLHYJ

铝合金芯交联聚乙烯绝缘架空电缆 Aluminum alloy conductor,XLPE insulated aerial cable

JKLGV

钢芯铝绞线聚氯乙烯绝缘架空电缆 ACSR conductor,PVC insulated aerial cable

JKLGY

钢芯铝绞线聚乙烯绝缘架空电缆 ACSR conductor, PE insulated aerial cable

JKLGYJ

钢芯铝绞线交联聚乙烯绝缘架空电缆 ACSR conductor, XLPE insulated aerial cable


产品标准 Standard of product
本产品按GB/T12527-2008标准生产,同时还可根据用户需要按国际电工委员会推荐的IEC标准、英国标准、德国标准和美国标准生产。
The cables are designed for aerial power lines and room-entrance wires with Uo/U up to and including 0.6/1kV
The product is manufactured according to the standard of GB/T12527-2008. At the same time ,it can also be manufactured according to IEC,BS,DIN and AEIC upon request.

使用特性Operating Characterastics
额定电压为1KV
Rated Voltage:1kv

电缆导体允许的长期最高工作温度
Max permissable continuous operating temperature of conductor

聚氯乙烯架空电缆:70℃
PVC insulated aerial cable: 70℃
聚乙烯绝缘架空电缆:75℃
PE insulated aerial cable: 75℃
交联聚乙烯绝缘架空电缆:90℃
XLPE insulated aerial cable:90℃
短路时(最长持续时间不超过5S)电缆导体的最高温度应不超过:
Max temperature of the conductor during short-circuit (5s maximum duration) shall not exceed :
聚氯乙烯绝缘架空电缆:160℃
PVC insulated aerial cable: 160℃
聚乙烯绝缘架空电缆:130℃
PE insulated aerial cable: 130℃
交联聚乙烯架空电缆:250℃
XLPE insulated aerial cable: 250℃
电缆敷设时环境温度应不低于:-20℃
The ambient temperature under installation should not be lower than -20℃

电缆的允许弯曲半径
电缆外径(D)小于25㎜,应不小于电缆外径的4倍
电缆外径(D)等于或大于25㎜,应不小于电缆外径的6倍
The bending radius of cable are recommended as follow:
When the diameter of cable is less than 25㎜:not less than 4 times of the cable’s OD
When the diameter of cable is more than and including 25mm: not less than 6 times of the cable’s OD
当电缆使用交流系统时,电缆的额定电压至少应等于该系统的额定电压;当电缆适地直流系统时,该系统的额定电压应不大于电缆额定电压的1.5倍
When the cable are used in the alternative current systerm,rated voltage of cables should be at least equal to the rated voltage of the system;when the cables are used in direct current system, rated voltage should not exceed than 1.5 times of the rated voltage of the cables
不同环境温度下载流量修正系数
Correction factor of current rating under different ambient temperature


材料
Material

电压
Rated voltage
kv

导体温度
Conductor temperature

实际环境温度℃Actual temperature

10

15

20

25

30

35

40

45

50

55

载流量修正系数
Corection factor of current rating for ambient termperature

PVC

1KV

70

1.52

1.44

1.36

1.28

1.19

1.09

1.00

0.89

0.78

0.65

PE

75

1.44

1.37

1.30

1.23

1.16

1.08

1.00

0.91

0.82

0.72

XLPE

90

1.32

1.26

1.21

1.16

1.11

1.05

1.00

0.93

0.89

0.80


Type

No. of core
Cross-section mm2
JKV JKLV JKLHV 1,2,4

16-240mm2

JKY JKLY JKLHY 1,2,4
JKYJ JKYJ JKLHYJ 1,2,4
JKLV JKLY JKLYJ 3+k
* K is the belt load bearing neutral conductor, no matter what elects.
电缆结构图 Diagram of Cable Structure



[ Go Back]
  电力电缆
  架空绝缘电缆
  裸导线
  矿用电缆&橡套电缆
  控制电缆
  特种电缆
  铁路信号电缆
   
   
  中华人民共和国商务部
  中国工商银行
  安徽出入境检验检疫局
  上海有色金属市场