产品标准 Standard of Product
该电缆参照按GB9331-88、GB/T13029-2003、IEC92-350、IEC332-3生产,同时还可根据用户需要按国际电工委员会推荐标准IEC、英国标准、德国标准及美国标准生产。
The cables are manufactured according to the standard of GB9331-88、GB/T13029-2003、IEC92-350、IEC332-3, at the same time, they are also can be manufactured according to the standard of IEC, BS, DIN and AEIC.
|
生产范围 PRODUCTION SCOPE
|
船用电缆型号的编制方法 Code Instruction of Types
类别用途 Usage &Type |
导体 Conductor |
绝缘 Insulation |
内护套 Inner Sheath |
外护套 Outer sheath
|
特性 Character |
燃烧特性定义代号 Code to Combustion Performance |
铠装代号 Armour Type |
外套代号 OuterSheath Type |
C-船用电缆系列 C-Shipboard Cable Serial CK-船用控制电缆 Shipboard control cable CH-船用对称式通信电缆 Shipboard symmetrical communication cable |
T-铜芯 T-Copper Core
| E-乙丙橡胶 ethylene-propylene rubber(EPR) J-交联聚乙烯 Cross-linked PE(XLPE) S-硅橡胶 Silicon Rubber X-天然、丁苯橡胶 Nature Rubber, Butadiene Styrene Rubber(NR,SBR) V-聚氯乙烯 polyvinyl chloride(PVC) |
V-聚氯乙烯 polyvinyl chloride(PVC) F-氯丁橡胶 Neoprene Rubber (CR) H-氯磺化聚乙烯 Chlorinated polyethylene(CPE) |
2-双钢带铠装 Double Steel Tape Armour 3-细钢丝铠装fine Steel Wire Armour 8-铜丝编织 Copper Wire Braided 9-钢丝编织 Steel wire Braided
|
0 - 2-聚氯乙烯 polyvinyl chloride(PVC) 3-聚乙烯 polyethylene 5-无卤交联聚烯烃 Halogen free cross-linked polyolefin 6-无卤非交联聚烯烃 Halogen free non-cross-linked polyolefin |
R-软结构 flexible structure M-水秘式 water-tight |
D-单根燃烧 Single Burn S-成束燃烧 Bunch Burn
N-耐火(单根燃烧) fire-resistant(single Burn) A-有烟、有酸、有毒 smoke,acid,Poison B-低烟、低酸、低毒 Low smoke,low acid,low poison C-无卤、低烟、低毒 Low smoke,low poison,no halogen |
|
型号举例 Sample of Type Code |
1、乙丙橡胶绝缘氯丁护套船用软电力电缆,额定电压 0.6/1KV,三芯,35 mm2,燃烧特性为D型,表示为:CEFR/DA-0.6/1 3×35 EPR insulated CR sheath flexible shipboard power cable,rated voltage 0.6/1KV ,3 cores,35mm2 Combustion Performance D,showed as CEFR/DA-0.6/1 3×35 |
2、乙丙橡皮绝缘氯磺化聚乙烯内套裸铜丝编织铠装船用电力电缆,额定电压 0.6/1KV,三芯,50 mm2,燃烧特性为DA型,表示为:CEH80/SA-0.6/1 3×50 EPR insulated CPE sheath copper wire braided armour shipboarded power Cable,rated voltage 0.6/1kv ,3 cores,50mm2,Combustion Performance DA,showed as CEH80/SA-0.6/1 3×50 |
3、乙丙橡皮绝缘氯磺化聚乙烯内套钢丝编织铠装聚氯乙烯外套船用电力电缆,额定电压 0.6/1KV,三芯,35 mm2,燃烧特性为DA型,表示为:CEH92/SA-0.6/1 3×35 EPR insualted CPE sheath,steel wire braided armour PVC outer sheath shipboard power cable,rated voltage 0.6/1kv,3 cores,35mm2,Combustion Performance DA,showed as CEH92/SA-0.6/1 3×35 |
4、聚氯乙烯绝缘和护套船用电力电缆,表示为:CVV/DA PVC insulated and sheath shipboard power cable,showed as CVV/DA |
5、交联聚乙烯绝缘PVC护套船用电力电缆,表示为:CJV/DA XLPE insulated and PVC sheath shipboard power cable |
6、天然丁苯橡皮绝缘船用电力电缆,表示为:CXF NR,SBR insulated shipboard power cable,showed as CXF |
|
使用特性 operating characteristic 1、额定电压:Uo/U 0.6/1KV 2、除软电缆可供移动设备使用外,其他电缆均为固定敷设,敷设时电缆的允许弯曲半径见下表: Except flexible cable be suitable for mobile equipment, the others should be for fixed installation.when laying,The allowed bending radius see the table below
电缆结构特征 Cable Structure |
电缆外径D Overall Dia. mm |
弯曲内半径 最小 mix. bending Radiusmm |
金属编织铠装型 Metal Braided Armour Type |
任意值 arbitrary value |
6D |
非铠装型 NON ARMOUR |
D≤25 |
4D |
D>25 |
6D |
3、电缆最低敷设温度:聚氯乙烯护套为-15℃,其他均为-20℃。 The ambient temperature under installation should not be below -15℃ for PVC sheath, others -20 ℃
4、电缆的燃烧特性Combustion Charaeteristies
单根垂直阻燃(DA)型电缆能经受GB12666.2(IEC332-1)规定的单根垂直燃烧试验。
Single Vertical flame retardant(DA) test can pass GB12666.2(IEC332-1)
成束阻燃(SA)型电缆能经受GB12666.5(IEC332-3)规定的成束燃烧试验。
bunched flame retardant test (SA) can pass GB12666.5(IEC332-3)
低烟低卤成束阻燃(SB)型电缆能经受GB12666.5(IEC332-3)规定的成束燃烧试验,且燃烧时烟浓度应符合GB12666.7(IEC1034)规定,燃烧折出气体HCl含量应≤100Mg/g(符合IEC754-1要求)。
Low smoke low halogen bunched flame retardant (SB)test can pass GB12666.5(IEC332-3),and Smoke density meet with GB12666.7(IEC1034) ,precipitation Gas of HCl ≤100Mg/g (meet with IEC754-1 requirement)
5、电缆的载流量是假定:四根电缆成整敷设于45℃环境温度中,且导体温度持续在允许工作温度下的计算值。
Current carrying capacity are calculated on Conditions ,air temperature 45℃,and conductor temperature under allowed continuous working temperatures
|
|
产品名称:交联聚乙烯绝缘船用电缆 0.6/1KV及以下 0.6/1kv and below XLPE insulated shipboard cable
型 号:CJV 80、90、82、92系列
用途 Usage:
本产品适用于河海船舶及水上建筑物传输电能,及话音信息,也可用于连接船用一般仪表和控制设备。
The product is suitable for transmitting power, the information transmission, interconnection of the instrumentation and control equipment in ships and over-water buildings. |
型号和名称 Types and Description
|
电缆结构尺寸,电气参数及近似重量 Cable Weight,Technical Properties,Weight 1、CEFR/DA(SA)型1芯、2芯、3芯电缆     CEFR/DA(SA) type Single core,Duplex core,Triplex Core Cable
导体结构 Cable Structure |
电缆计算外径 Cable Overall Dia. (mm) |
电缆计算重量 Cable Weight kg/km |
导体电阻 Conductor Resistance ≤Ω/Km |
绝缘电阻 Insulation Resistance ≥MΩ·Km |
载流量 Current Capacity A |
截面mm2 Nominal Cross Section
|
根数线径 Strands No./Dia.( mm) |
1芯Core 1- |
2芯Cores 2- |
3芯Cores 3- |
1芯Core 1- |
2芯Cores 2- |
3芯Cores 3- |
20℃ |
20℃ |
85℃ |
1芯Core 1- |
2芯Cores 2- |
3芯Cores 3- |
1.0 |
32/0.20 |
5.8 |
10.4 |
11.0 |
45 |
115 |
136 |
20.0 |
1350 |
1.350 |
16 |
14 |
11 |
1.5 |
30/0.25 |
6.1 |
10.9 |
11.8 |
52 |
132 |
164 |
13.7 |
1210 |
1.210 |
20 |
17 |
14 |
2.5 |
49/0.25 |
6.5 |
12.0 |
12.7 |
64 |
169 |
207 |
8.21 |
1031 |
1.031 |
28 |
24 |
20 |
4 |
56/0.30 |
7.0 |
13.0 |
13.8 |
83 |
214 |
268 |
5.09 |
889 |
0.889 |
38 |
32 |
27 |
6 |
84/0.30 |
8.2 |
15.4 |
16.6 |
113 |
294 |
379 |
3.39 |
660 |
0.660 |
48 |
41 |
34 |
10 |
84/0.40 |
9.5 |
18.1 |
19.3 |
168 |
437 |
561 |
1.95 |
523 |
0.523 |
67 |
57 |
49 |
16 |
126/0.40 |
10.7 |
20.3 |
21.7 |
231 |
588 |
746 |
1.24 |
448 |
0.448 |
90 |
77 |
63 |
25 |
196/0.40 |
12.8 |
24.7 |
26.6 |
340 |
875 |
1157 |
0.795 |
425 |
0.425 |
120 |
102 |
84 |
35 |
276/0.40 |
14.7 |
28.4 |
30.4 |
459 |
1170 |
1537 |
0.565 |
356 |
0.356 |
145 |
123 |
102 |
50 |
396/0.40 |
17.0 |
32.8 |
35.3 |
640 |
1612 |
2150 |
0.393 |
353 |
0.353 |
180 |
153 |
126 |
70 |
360/0.50 |
19.6 |
38.4 |
41.3 |
877 |
2237 |
2988 |
0.277 |
339 |
0.339 |
225 |
191 |
158 |
95 |
475/0.50 |
21.5 |
41.9 |
45.1 |
1118 |
2806 |
3774 |
0.210 |
305 |
0.305 |
275 |
231 |
193 |
120 |
608/0.50 |
23.2 |
45.6 |
49.1 |
1384 |
3458 |
4674 |
0.164 |
276 |
0.276 |
320 |
272 |
224 |
150 |
756/0.50 |
26.8 |
- |
56.7 |
1729 |
- |
5888 |
0.132 |
265 |
0.265 |
365 |
- |
256 |
185 |
975/0.50 |
28.7 |
- |
60.6 |
2092 |
- |
7056 |
0.108 |
276 |
0.276 |
415 |
- |
291 |
240 |
1221/0.50 |
31.7 |
- |
- |
2712 |
- |
- |
0.0817 |
272 |
0.272 |
490 |
- |
- |
300 |
1525/0.50 |
35.9 |
- |
- |
3373 |
- |
- |
0.0654 |
259 |
0.259 |
560 |
- |
- |
2、CEFR/DA(SA)型多芯电缆 CEFR/DA(SA) type Multi-cores Cable
导体结构 Conductor Structure |
电缆外径 Overall Dia. (mm) |
电缆计算重量 Cable Weight kg/km |
导体电阻 COnductor Resistance ≤Ω/Km 20℃ |
绝缘电阻 Insulation Resistance ≥MΩ·km |
芯数×标称截面 Cores NO×Nominal Cross Section mm2 |
根数/线径 Strands NO./Dia. (mm) |
标准值 .Nominal Value |
最大值 Max.Value |
20℃ |
85℃ |
4×1 |
32/0.20 |
12.2 |
14.5 |
157 |
20.0 |
1350 |
1.35 |
5×1 |
13.3 |
15.5 |
192 |
7×1 |
14.6 |
17.0 |
242 |
10×1 |
18.6 |
21.5 |
342 |
12×1 |
19.2 |
22.0 |
377 |
14×1 |
20.4 |
23.5 |
437 |
16×1 |
21.5 |
24.5 |
495 |
19×1 |
22.6 |
26.0 |
562 |
24×1 |
26.8 |
30.5 |
757 |
27×1 |
27.4 |
31.0 |
815 |
30×1 |
28.4 |
32.5 |
889 |
33×1 |
29.7 |
33.5 |
985 |
37×1 |
30.8 |
35.0 |
1076 |
4×1.5 |
30/0.25 |
12.8 |
15.0 |
183 |
13.7 |
1210 |
1.20 |
5×1.5 |
14.0 |
16.5 |
226 |
7×1.5 |
15.4 |
18.0 |
287 |
10×1.5 |
19.6 |
22.5 |
408 |
12×1.5 |
20.5 |
23.5 |
462 |
14×1.5 |
21.5 |
24.5 |
524 |
16×1.5 |
22.7 |
26.0 |
596 |
19×1.5 |
24.1 |
27.5 |
691 |
24×1.5 |
28.6 |
32.5 |
924 |
27×1.5 |
29.2 |
33.0 |
997 |
30×1.5 |
30.2 |
34.5 |
1088 |
33×1.5 |
31.6 |
36.0 |
1206 |
37×1.5 |
32.8 |
37.5 |
1319 |
4×2.5 |
49/0.25 |
13.9 |
16.5 |
234 |
8.21 |
1031 |
1.031 |
5×2.5 |
15.4 |
18.0 |
299 |
7×2.5 |
16.7 |
19.5 |
372 |
10×2.5 |
21.6 |
24.5 |
549 |
12×2.5 |
22.3 |
25.5 |
607 |
14×2.5 |
23.7 |
27.0 |
703 |
16×2.5 |
25.0 |
28.5 |
803 |
19×2.5 |
26.5 |
30.0 |
930 |
24×2.5 |
31.2 |
35.5 |
1221 |
27×2.5 |
32.1 |
36.5 |
1335 |
30×2.5 |
33.3 |
37.5 |
1461 |
33×2.5 |
34.8 |
39.5 |
1619 |
37×2.5 |
36.1 |
41.0 |
1774 |
3、CEF/DA(SA)、CEF80/DA(SA)、CEF82/DA(SA)型1芯、2芯、3芯电缆 CEF/DA(SA)、CEF80/DA(SA)、CEF82/DA(SA)
Single Core/Duplex Cores/Triplex Core
芯数 Cores NO |
导 体 CONDUCTOR |
电缆计算外径 Overall Dia. (mm) |
电缆计算重量 Cable Weight (kg/km) |
导体电阻 Conductor Reisstance ≤Ω/Km |
绝缘电阻 Insulation Reisstance
|
载流量 Current Capacity |
截 面 Nominal Cross Section mm2 |
根数/线径 strands NO./Dia. (mm) |
CEF |
CEF80 |
CEF82 |
CEF |
CEF80 |
CEF82 |
20℃ |
20℃ |
85℃ |
A |
1 |
1 |
7/0.43 |
5.8 |
6.8 |
8.4 |
44 |
77 |
107 |
18.2 |
1382 |
1.382 |
16 |
1.5 |
7/0.52 |
6.0 |
7.0 |
8.6 |
51 |
86 |
117 |
12.2 |
1230 |
1.230 |
20 |
2.5 |
7/0.68 |
6.5 |
7.5 |
9.1 |
65 |
102 |
135 |
7.56 |
1031 |
1.031 |
28 |
4 |
7/0.85 |
7.0 |
8.0 |
9.6 |
83 |
123 |
158 |
4.70 |
881 |
0.881 |
38 |
6 |
7/1.04 |
7.6 |
8.6 |
10.2 |
107 |
149 |
187 |
3.11 |
759 |
0.759 |
48 |
10 |
7/1.35 |
8.5 |
9.5 |
11.1 |
153 |
201 |
242 |
1.84 |
620 |
0.620 |
67 |
16 |
7/1.70 |
9.8 |
10.8 |
12.6 |
221 |
275 |
326 |
1.16 |
514 |
0.514 |
90 |
25 |
7/2.14 |
11.5 |
13.0 |
14.8 |
329 |
425 |
491 |
0.734 |
496 |
0.496 |
120 |
35 |
19/1.53 |
12.9 |
14.4 |
16.2 |
438 |
546 |
619 |
0.529 |
427 |
0.427 |
145 |
50 |
19/1.78 |
14.8 |
16.3 |
18.3 |
584 |
707 |
796 |
0.391 |
429 |
0.429 |
180 |
70 |
19/2.14 |
17.0 |
18.5 |
20.5 |
813 |
953 |
1054 |
0.270 |
412 |
0.412 |
225 |
95 |
19/2.52 |
19.1 |
20.6 |
22.8 |
1090 |
1246 |
1368 |
0.195 |
357 |
0.357 |
275 |
120 |
37/2.03 |
20.7 |
22.2 |
24.4 |
1341 |
1510 |
1640 |
0.154 |
325 |
0.325 |
320 |
150 |
37/2.25 |
22.8 |
24.3 |
26.7 |
1642 |
1829 |
1983 |
0.126 |
323 |
0.323 |
365 |
185 |
37/2.52 |
25.3 |
26.8 |
29.2 |
2046 |
2252 |
2421 |
0.100 |
320 |
0.320 |
415 |
240 |
61/2.25 |
28.5 |
30.0 |
32.6
|
2657 |
2889 |
3091 |
0.0762 |
311 |
0.311 |
490 |
300 |
61/2.52 |
31.5 |
33.5 |
36.1 |
3306 |
3649 |
3886 |
0.0607 |
304 |
0.304 |
560 |
2 |
1 |
7/0.43 |
10.3 |
11.8 |
13.6 |
113 |
201 |
262 |
18.2 |
1382 |
1.382 |
14 |
1.5 |
7/0.52 |
10.8 |
12.3 |
14.1 |
130 |
222 |
285 |
12.2 |
1230 |
1.230 |
17 |
2.5 |
7/0.68 |
12.0 |
13.5 |
15.3 |
171 |
272 |
341 |
7.56 |
1031 |
1.031 |
24 |
4 |
7/0.85 |
13.0 |
14.5 |
16.5 |
214 |
324 |
404 |
4.70 |
881 |
0.881 |
32 |
6 |
7/1.04 |
14.2 |
15.7 |
17.7 |
271 |
389 |
475 |
3.11 |
759 |
0.759 |
41 |
10 |
7/1.35 |
16.2 |
17.7 |
19.7 |
389 |
523 |
620 |
1.84 |
620 |
0.620 |
57 |
16 |
7/1.70 |
18.5 |
20.0 |
22.2 |
547 |
700 |
818 |
1.16 |
514 |
0.514 |
77 |
25 |
7/2.14 |
22.2 |
23.7 |
26.1 |
817 |
998 |
1148 |
0.734 |
496 |
0.496 |
102 |
35 |
19/1.53 |
24.8 |
26.3 |
28.7 |
1073 |
1276 |
1442 |
0.529 |
427 |
0.427 |
123 |
50 |
19/1.78 |
28.3 |
29.8 |
32.4 |
1419 |
1650 |
1850 |
0.391 |
429 |
0.429 |
153 |
70 |
19/2.14 |
33.1 |
35.1 |
37.9 |
1994 |
2354 |
2617 |
0.270 |
412 |
0.412 |
191 |
95 |
19/2.52 |
37.1 |
39.1 |
42.1 |
2634 |
3036 |
3346 |
0.195 |
357 |
0.357 |
234 |
120 |
37/2.03 |
40.5 |
42.5 |
45.7 |
3237 |
3676 |
4031 |
0.154 |
325 |
0.325 |
272 |
3 |
1 |
7/0.43 |
10.9 |
12.4 |
14.2 |
135 |
228 |
291 |
18.2 |
1382 |
1.382 |
11 |
1.5 |
7/0.52 |
11.7 |
13.2 |
15.0 |
163 |
262 |
329 |
12.2 |
1230 |
1.230 |
14 |
2.5 |
7/0.68 |
12.7 |
14.2 |
16.0 |
210 |
317 |
389 |
7.56 |
1031 |
1.031 |
20 |
4 |
7/0.85 |
13.8 |
16.0 |
17.3 |
269 |
384 |
469 |
4.70 |
881 |
0.881 |
27 |
6 |
7/1.04 |
15.3 |
17.3 |
18.8 |
353 |
480 |
572 |
3.11 |
759 |
0.759 |
34 |
10 |
7/1.35 |
17.3 |
18.8 |
20.8 |
504 |
647 |
750 |
1.84 |
620 |
0.620 |
47 |
16 |
7/1.70 |
19.7 |
21.2 |
23.4 |
721 |
883 |
1008 |
1.16 |
514 |
0.514 |
63 |
25 |
7/2.14 |
23.8 |
25.3 |
27.7 |
1097 |
1292 |
1452 |
0.734 |
496 |
0.496 |
84 |
35 |
19/1.53 |
26.5 |
28.0 |
30.4 |
1436 |
1653 |
1829 |
0.529 |
427 |
0.427 |
102 |
50 |
19/1.76 |
30.5 |
32.5 |
35.3 |
1923 |
2255 |
2499 |
0.391 |
429 |
0.429 |
126 |
70 |
19/2.14 |
35.6 |
37.6 |
40.6 |
2710 |
3096 |
3394 |
0.270 |
412 |
0.412 |
158 |
95 |
19/2.52 |
39.9 |
41.9 |
45.1 |
3602 |
4034 |
4384 |
0.195 |
357 |
0.357 |
193 |
120 |
37/2.03 |
43.6 |
45.6 |
48.8 |
4441 |
4913 |
5292 |
0.154 |
325 |
0.325 |
224 |
150 |
37/2.25 |
48.2 |
50.2 |
53.6 |
5446 |
5966 |
6405 |
0.126 |
323 |
0.323 |
256 |
185 |
37/2.52 |
53.3 |
55.3 |
59.1 |
6762 |
7337 |
7869 |
0.100 |
320 |
0.320 |
291 |
船用电缆导体电阻 Shipboard Cable Conductor Resistance
船用电力电缆单芯连续工作制的载流量(环境温度45℃)Shipboard power Cable current capacity for single core long time operating
不同环境空气温度下的修正系数Auxiliary value of environment and air temperature
|
|
|
|
|